Emergency lights, I believe all of us should be familiar with them. After all, as soon as you hear the name, you must know it is for an emergency! Usually, they are very easy to be ignored. But once there is a power failure, the emergency lights will show their role immediately! Although everyone knows about emergency lights, few people know how to install them. Today, I will show you the correct specifications of the installation for emergency lights.
Step 1:
Emergency lights are installed in the exit of evacuation passage. They are usually above the door frame of the exit. Or they are on the wall of corridor, safety exit and corridor light. It's almost two meters above the ground.
In the places like large electronic market or shopping centers, they will be installed with the double-headed lights. This kind of emergency light can be directly hanged on the wall. Or just install them on the column above.
Step 2:
Because of the wrong wiring mode, the emergency lights can not be used normally. In the supervision and inspection, the staff found these conditions occur repeatedly. So you must pay attention to the way of connecting wires. Use a dedicated line that is specially prepared for emergency lights. And do not set additional switches halfway.
Step 3:
In the event of a fire, the closer to the ground, the less smoke there is. And also, the more oxygen there will be. The instinct to evacuate is usually to stoop and walk or simply crawl. So the high light for a local place is much more effective than a high installation in this situation. A ground-mounted model may be recommended. That means where emergency lighting is provided near the ground.
Location of Installation
We all know that emergency lights are very important. But where should they be installed rightly? It is suitable for a height of about 2.2 meters. Of course, you still need to decide according to the actual situation of the place. The overall space of the place is very large, and the density of emergency lights will increase. So the height of the installation needs to be adjusted accordingly. You need to check the relevant provisions of the fire inspection and acceptance department.
In terms of position, it is necessary not to be hit by objects and not to be blocked. If the position is too high, the brightness will be affected. And it brings trouble to repair and debug the emergency lights.
In life, do not underestimate the role of emergency lights. When installing the emergency lights, you must pay close attention to the installation position. And you still must learn the steps of installation well. Take it seriously. In case of power failure, emergency lights are very important. Only by the correct steps of installation, emergency lights will show their real role. That they help people feel the light and accompany them through the darkness.